Welcome to UpcomingEvents.com!! We hope to see you at an event SOON!
Search

Select Region

Featured Regions

Philadelphia, PA Baltimore, MD Atlantic City, NJ

Not what you're looking for? See All Cities

Or

Search by Zip

T440x300

Pulse Oximetry SPO2 Heart Rate Blood Oxygen Saturation Monitor Meter Sensor

  • This item is sold through the Contec Medical Systems USA, Inc. operated by Contec Medical Systems USA, Inc..
  • The merchant is solely responsible to purchasers for the fulfillment, delivery, care, quality, and pricing information of the advertised goods and services.
  • The product is new.
  • This is a FINAL SALE; no returns or refunds unless defective.
  • Shipping and handling charges will be Free.
  • United States (excluding Alaska & Hawaii) Shipments only.
  • Does not ship to PO boxes.
  • Orders are typically delivered in 5-10 business days.

Pulse Oximetry SPO2 Heart Rate Blood Oxygen Saturation Monitor Meter Sensor

Pulse Oximetry SPO2 Heart Rate Blood Oxygen Saturation Monitor Meter Sensor

1.Introduction
CMS50M Pulse Oximeter is a portable equipment adopting advanced technology, it mainly checks SpO2 and PR value through the finger, which provides advanced, non-invasive and scientific means for quantitative measurement of oxygen saturation.
CMS50M Pulse Oximeter is applicable for use in plateau area, community healthcare, oxygen bar, Fitness clubs, physical training room, family and medical institution, etc.

2.Features
1) Can measure SpO2 and Pulse Rate accurately
2) SpO2 and Pulse Rate display,bar graph display
3) Battery voltage low indication
4) Shut off automatically when no signal
3.Performance
SpO2 measurement range: 0%~100%
Accuracy: 70%~100%: ±2%
0%~69%: unspecified
PR measurement range: 30bpm~250bpm
Accuracy: ±2bpm or ±2%, whichever is greater.
Resolution:
SpO2: 1%
PR: 1bpm
Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2%, whichever is greater.
Resistance to surrounding light: The deviation between the value measured in the condition
of man-made light or indoor natural light and that of darkroom is less than ±1%.
Working current: ≤25mA
Power supply: two "AAA" batteries
Safety classification: type BF applied part

4.Physical characteristic
Dimension: 57mm(L) × 34mm(W) × 31mm(H)


Pulse Oximetry SPO2 Heart Rate Blood Oxygen Saturation Monitor Meter Sensor

  • Dimensions: 31.0 millimeters (H) x 34.0 millimeters (W) x 57.0 millimeters (L)
  • Weight: 100.0 grams
  • Made in China

Get this Deal
Top